Horiba Pentra C200 Analyzer

More Info

Horiba Pentra C200 Analyzer

Horiba Pentra C200 Analyzer

Horiba Pentra C200 Analyzer
Overview

Fixed cycles provide continuous throughput of 90 colorimetric tests/hour
Optional high throughput ISE module (270 tests/hour)
Reagent management with unique “Pentra” cassette
Fully automatic cuvette management – 2 racks of 96 single-use cuvettes
Dedicated waste compartment for used cuvettes and contaminated liquid
Integrated computer and cooling unit (Peltier)
Product Description

Analysis Method Types:
Spectrophotometry: Colorimetry and Turbidimetry
Potentiometry: Direct (Serum or Plasma) and Indirect (Urine)
15 parameters per reagent tray
Optional ISE Module (Na+, K+, Cl-)
Maximum Throughput: up to 360 test/h (140 tests/h in standard configuration)
CE Marked
Sample Handling

Sample Capacity: 15 positions in a refrigerated compartment
Dedicated stat position in Random access
Positive Sample Identification: Integrated Barcode Reader
Sampling Needle: Level, and Shock Detection
Sample Collection Format: 2, 3, 4, 5, 7 and 10 mL (diameter: from 13 to 6mm)
Sample Specimen: Serum, Plasma, Urine, CSF, Homogeneous Fluids
Sample Volume: 2 to 45 µL (0.1 µl increment)
Automatic Sample Dilution: from 1/2 to 1/30,625
ISE: 20 µL (Indirect) or 93 µL (Direct)
Automatic Post Concentration: from x2.0 to x 20.0
Automatic Re-run
Calibrator/Control Handling

Calibrator/Controls Positioning on Sample Tray in the Refrigerated compartment
Automatic Standard Dilution Series:
Dilution Factors: Main Direct 1/2 – 1/175
Dilution Factors: Main Indirect 1/176 – 1/30 6258
Reagent Handling

15 parameters onboard in a closed refrigerated area (8-15°C)
Positive Reagent Identification: Integrated Barcode Reader
Reagent Needle: Level Detection and shock detection
Reagent management with cassettes: Automated Reagent Onboard Stability Check plus continuous test countdown check by capacitive effect.
Reagent Volume: from 20 to 350 µL
Reaction System

Reaction Volume: 120 to 450 µL
Reaction Temperature: Air bath at 37°C
Photometer Reaction Cycle:20 seconds
Homogenization with Stirring Paddle
Reaction Time: 1 to 29 cycles
Disposable Acrylic Cuvettes
Automatic Cuvette Changer
Cuvette Capacity: 192 cuvettes (2 racks of 96 cuvettes)
7 Integrated Calculation Algorithms

As A Certified Medical Device Manufacturer

licensed through the California State Department of Public Health, FDA Division, our remanufactured equipment is guaranteed to meet the most stringent requirements of this governing body. Our superior supply-chain process allows us to provide a one year parts, labor, and travel warranty. ClearChem Diagnostics takes pride in ensuring each re-certified system will look and perform as new!

You can view our licenses here